As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PERFORMED INSPECTION IAW (IAW 8-500-7-5001-1P) FOUND DOUBLER LENGTH 12 INCHES WITH 6 INCHES LT INT FUSE AT STA 695 TO STA 675 LONG 51 TO LONG 52. STRIPPED PAINT IAW SRM 51-21-01 VOL 2 PAR 33. REMOVED RIVET AND INSTALLED FASTENERS PER SRM 52-20-00 FIG 13 VOL 1, TREATED AND PROTECTED AREA IAW SRM 51-21-01 VOL 2.