What was found
RIGHT FUSELAGE EXTERNAL SKIN HAS A DENT AT STA BS 414 ON STRINGER STR 25-R. CHECKED DENT AND FOUND TO BE OUT OF LIMITS IAW B727 SRM 53-30-1. CUT OUT DAMAGE IAW B727 SRM 53-30-3. FABRICATED DOUBLER AND FILLERS IAW B727 SRM 53-30-3. ALODINED AND PRIMED REPAIR PARTS IAW B727 SRM 51-10-2. INSTALLED REPAIR DOUBLER AND FILLERS IAW B727 SRM 53-30-3. THIS IS A MAJOR REPAIR. SIGNED BY TIMCO MECH NR 110188 AND QC178.