As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME 44 BETWEEN RT STRINGERS 6 AND 7 HAS PUNCTURED DAMAGE APPROX 1.00 INCH LENGTH WITH DEEP SCRATCHES. DRILLED 0.75 INCH HOLE TO REMOVE DAMAGE. DEBURRED HOLE. NDT FOR CRACKS. NO CRACKS NOTED. ALODINED AND PRIMED AREA. ALL WORK PERFORMED IAW EA 6-5310-93421 AND DOCUMENTED ON NRC N00109.