What was found
CABIN FLOORBEAM, UPPER T-CAP CORRODED AT STA BS 440 BL 0 - RBL 24. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1 FIGURE 5. REMOVED DAMAGED T-CAP FROM RBL-8 TO LBL 8 STA BS 440 IAW SRM 53-10-8 FIGURE 3. REMOVED CORROSION FROM RBL 8 TO RBL 24 IAW SRM 51-10-6 AND FOUND WITHIN LIMITS IAW SRM 53-10-1 FIGURE 5. FABRICATED, LOCATED AND DRILLED THE UPPER CHORD SECTION, SUPPORT ANGLES AND REINFORCEMENT STRAPS IAW SRM 53-10-8 FIGURE 3. ALODINED AND PRIMED IAW SRM 51-10-2. PAINTED IAW SRM 51-10-2. INSTALLED REPAIR PARTS IAW SRM 51-30-2 AND 53-10-8 FIGURE 3.