What was found
MAIN DECK FLOORBEAM CORRODED AT STA BS 720D FROM LBL27 TO LBL44. DAMAGE FOUND TO BE OUT OF LIMITS IAW B727 SRM 53-10-1 FIGURE 5. REMOVED STANCHION AND INTERCOSTAL BETWEEN STA BS 720D AND STA BS 720E TO FOM IAW B727 SRM 51-30-2. FABRICATED UPPER CHORD REPAIR IAW B727 SRM 53-10-8 FIGURE 4. ALODINED AND PRIMED REPAIR PARTS IAW B727 SRM 51-10-2. INSTALLED UPPER CHORD REPAIR IAW B727 SRM 53-10-8 FIGURE 4. REINSTALLED STANCHION AND INTERCOSTAL IAW B727 SRM 51-30-2. THIS IS A MAJOR REPAIR. REFERENCE FEDEX SNRM N00780, SIGNED BY TIMCO MECH NR 110174 AND QC261.