What was found
FOUND CABIN FLOORBEAM UPPER TEE CAP CORRODED AT STA BS400 BETWEEN BL 0 AND LBL 12. DAMAGE FOUND TO BE BEYOND LIMITS IAW B727 SRM 53-10-1 FIGURE 5. REMOVED DAMAGED UPPER CHORD IAW B727 SRM 53-10-8 FIGURE 3. FABRICATED REPAIR PARTS IAW B727 SRM 53-10-8 FIGURE 3. ALODINED AND PRIMED REPAIR PARTS IAW B727 SRM 51-10-2. INSTALLED REPAIR PARTS IAW B727 SRM 51-30-2. THIS IS A MAJOR REPAIR SIGNED BY TIMCO MECH NR 3476 AND QC261 REFERENCE FEDEX SNRM N00604.