What was found
FOUND DOUBLER DIAMETER 3.5 INCH RT INT FUSELAGE AT STA 809 LONG 50. PERFORMED INSPECTION ON REPAIR IAW SRM 53-20-00 FIG 13 SHT 4 VOL 1 AND EA NR 8-5330-93234. FOUND IN COMPLIANCE WITH CRITERIA REQUEST BY EO NR 8-5100-7-5001 P1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DOUBLER DIAMETER 3.5 INCH RT INT FUSELAGE AT STA 809 LONG 50. PERFORMED INSPECTION ON REPAIR IAW SRM 53-20-00 FIG 13 SHT 4 VOL 1 AND EA NR 8-5330-93234. FOUND IN COMPLIANCE WITH CRITERIA REQUEST BY EO NR 8-5100-7-5001 P1.