What was found
LEFT HAND WING UPPER TRAILING EDGE PANEL FOUND BULGING AT XORS 1036. REMOVED CORROSION AT LEFT HAND WING UPPER TRAILING EDGE PANEL, XORS 1036 AS PER SRM 51-21-011 VOLUME II. ORIGINAL THICKNESS=0.140, MATERIAL REMOVED 0.100, REMAINING THICKNESS=0.040", FOUND EXCEEDED LIMIT AS PER SRM 57-20-00, FIGURE 16 VOLUME I. REPAIR CARRIED OUT AS PER FEDEX EA 1-5710-90697.