What was found
AFT PIT MAIN DECK FLOORBEAM HAS CORROSION AT FASTENER CLIP AT STA, BS 950F, LBL21.0. REMOVED CORROSION IAW SRM 51-10-6 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1 FIGURE 4. REMOVED AND REPLACED FLOORBEAM UPPER TEE CAP SECTION FROM LBL8 TO LBL70 IAW STANDARD REWORK DRAWING SR27-53- 034E. THIS IS A MAJOR REPAIR SIGNED BY MECH NR 1269 AND QC352. REF N00557.