What was found
FOUND PREVIOUSLY REPAIR AT STA 950A, STR 29L WAS ACCOMPLISHED IAW SRM 53-30-3, FIG 3 PAGE 13, BASED ON EXTERNAL VISUAL EVALUATION OF LOCATION, SHAPE, SIZE, FASTENER SPACING, NUMBERS AND SPACING, MATERIAL THICKNESS AND GENERAL WORKMANSHIP, REPAIR IS CLASSIFIED AS MAJOR REPAIR.