What was found
FOUND PREVIOUS REPAIR ON UPPER LEADING EDGE OF LEFT WING AT NR 3 LEADING EDGE SLAT WAS ACCOMPLISHED IAW SRM 57-30-4, FIG 1. BASED ON AN EXTERNAL EVALUATION CONSISTED OF LOCATION, SHAPE, SIZE, MATERIAL TYPE AND THICKNESS, FASTENER SPACING AND NUMBERS, GENERAL WORKMANSHIP, REPAIR CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.