What was found
FOUND PREVIOUSLY REPAIR INSTALLED AT STA.1323 LT SIDE BELOW PYLON TRAILING EDGE WAS ACCOMPLISHED IAW SRM 51-40-2, FIG 1, BASED ON AN EXTERNAL EVALUATION CONSISTS OF LOCATION, SIZE, SHAPE, MATERIAL TYPE AND THICKNESS, FASTENERS NUMBERS AND SPACING, GENERAL WORKMANSHIP AND REPAIR IS CLASSIFIED AS MAJOR.