What was found
FOUND PREVIOUSLY REPAIR, INSTALLED AT STA 1330 ABOVE AIRSTAIRS CUTOUT RT SIDE WAS ACCOMPLISHED IAW SRM 53-30-3 FIG 3, BASED ON AN EXTERNAL VISUAL EVALUATION CONSISTS OF LOCATION, SHAPE, SIZE, MATERIAL THICKNESS AND TYPE, FASTENER NUMBERS AND SPACING, GENERAL WORKMANSHIP AND REPAIR IS CLASSIFIED AS MAJOR.