FOUND PREVIOUSLY REPAIR INSTALLED AT STA 1130, STR 22L WAS ACCOMPLISHED IAW SRM 53-30-3 FIG 1 BASED ON AN EXTERNAL VISUAL EVALUATION CONSISTS OF LOCATION, SHAPE, SIZE, MATERIAL TYPE AND THICKNESS, FASTENER NUMBERS AND SPACING, GENERAL WORKMANSHIP AND REPAIR IS CLASSIFIED AS MAJOR.