SDR 06FDEA0191

Service difficulty report · Hinge Fitting · Doug MD11

Difficulty date
January 15, 2006
Submitted
January 16, 2006
Operation
Air carrier
Aircraft
N607FE
Make and model
Doug MD11
Aircraft serial
48547
Aircraft time
47,138 hours, 10,726 cycles
Part
Hinge Fitting
Condition
Corroded
Location
Zone 600
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT HAND WING OUTBOARD FLAP INBOARD HINGE FITTING (ARC1984) AFT MOUNT NR 2 BOLT HOLE FOUND CORROSION. REMOVED AND REPAIR CARRIED OUT PER FEDEX E.A. #1-5750-90720, TITLE: WINGS - OUTBOARD TRAILING EDGE FLAP - RIGHT HAND INBOARD SUPPORT STRUT - CORROSION REPAIR. ORIGINAL HOLE DIAMETER = 0.519", FINAL HOLE DIAMETER = 0.579". REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.