What was found
LT WING INBD FLAP (FLAP SIDE) OUTBD PIVOT PIN ATTACHMENT OUTBD STRAP SURFACE FOUND CORRODED. LT WING I/B FLAP O/B HINGE O/B STRAP PIVOT STRAP SURFACE CORROSION REMOVED AND FOUND EXCEEDED LIMIT AS PER CMM 57-52-03 PG 442-444. ORIGINAL THK 0.273" REMAINING THK 0.198" MATERIAL REMOVED 0.075" MIN, ALLOWABLE THK 0.205". NEW STRAP FABRICATED AS PER DAC DWG ARC 2518-501. OLD STRAP REMOVED AND REPLACED WITH NEW FABRICATED STRAP AS PER SRM 51-33-01 VOL II AND DAC DWG ARC 2512. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.