What was found
MAIN DECK CARGO, FOUND L3 DOOR CUTOUT LOWER FORWARD AND AFT CORNER SEAL LAND LOCATION WITH CORROSION. MAIN DECK CARGO LT HAND DOOR FORWARD AREA CORROSION REMOVED AS PER SRM 51-21-01 VOLUME II. MATERIAL THICKNESS = 0.270", REMAINING THICKNESS = 0.235", MATERIAL REMOVED = 0.035" AND FOUND WITHIN LIMIT AS PER SRM 53-50-00 FIGURE 17 VOLUME I. AFT AREA MEASURED, MATERIAL THICKNESS = 0.270", REMAINING THICKNESS = 0.196", MATERIAL REMOVED = 0.074" AND FOUND EXCEEDED LIMIT AS PER SRM 53-50-00 FIGURE 17 VOLUME I. AFT AREA CARRIED OUT REPAIR AS PER SRM 53-50-00 VOLUME I FIGURE 17. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.