What was found
LT WING INT L/E FOUND 2 DEEP WEAR ON SUPPORT TRACK NR 6. BLENDED OUT AREAS OF SUPPORT IAW SRM 57-00-01 PAGE 1 FIG 14 VOL 1. RECORDED MATERIAL REMAINING ON REWORKED AREAS (AREA 1 .8751" ) AND ( AREA 2 .580" ), NOM THK OF DAMAGES AREA IS 1" IAW DWG ARB1200. BLEND OUT IS .1249" AND 0.020", THE BLENDED OUT IS 12% AND 2% SO THE BLEND OUT IS WITHIN LIMITS BECAUSE THE MAX IS 20% IAW SRM 57-00-01 FIG 1A VOL1. REPROTECTED AREAS IAW SRM 51-21-01 PAG 21-25 VOL 2 AND INSTALLED MISSING BLOCK PROTECTION P/N ARB1180-1 IAW DWG ARB0186.