What was found
MAIN DECK CARGO, ON FLOOR PANEL OPEN UP FOUND UNDERFLOOR STRUCTURE AT STA 1225 RBL 4 WITH CORROSION. CORROSION ON MAIN DECK CARGO ON FLOOR PANEL UNDERFLOOR STRUCTURE AT STA 1225 RBL 4 REMOVED AS PER SRM 51-21-01 VOLUME II AND FOUND EXCEEDED LIMIT AS PER SRM 57-20-00 FIGURE 12 VOLUME I. ORIGINAL THICKNESS = 0.177", REMOVED MATERIAL = 0.036" AND THICKNESS REMAINED = 0.141 AND REPAIR CARRIED OUT AS PER FEDEX E.A. 1-5720-104805, REPAIR CLASSIFIED AS MINOR PER GMM 6 -2-100.