As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT WING LOWER SURFACE PANEL 550NB PANEL LAND HAS ONE EA DRILL START NEXT TO HOLE COMPLIED WITH EA 6-5730-104975, OPENED HOLE TO 0.402, COLD WORKED AND FINAL REAMED TO 0.418. FABBED AND INSTALLED BUSHING AND DRILLED NEW HOLE IAW TD/J1/S1/03541/2006.