What was found
PDIS 728 77-10 0804 13OCT06 GSO RECD ENG 2 N1 MODE. ONLY MAINTENANCE - CLEARED ITSELF ON T/O ROLL RECD SAME WARNING. REFECT T/O AT 60KTS. FOLLOWED ALL ECAM/RED TABS. FADEC WAS SELECTED TO N1 MODE FOR BOTH ENGINES. FACT 13OCT06 04:47 GSO R REMOVED AND REPLACED FWC2 RAN NR 1 AND NR 2 ENGINES IAW JRH IN EPR MODE OPS NORMAL AND N1 MODE WAS ABLE TO CLEAR BOTH ENGINE N1 MODE ADVISORIES. ALSO REF 31-53-34 FWC REMOVED AND REPLACED 22-24-00 AFS/LAND TEST OK. R/I 13OCT06 04:48 GSO R R/I FROM FACT PREMATURE REMOVAL/INSTALLATION OFF MFG 35-0B5-3005-313 POS. BOT SRL 1354 TAG B31048 ON MFG 35-0B5-3005-313 SRL 1331 TAG 6A8422.