What was found
MAIN DECK CARGO COMPARTMENT, MAIN FUSELAGE FRAME AT STA 1741 ABOUT LONGERON 12R AREA FOUND DENTED. DENT REPAIRED AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. INITIAL INSPECTION AT 14,500 CYCLES AND REPETITIVE INSPECTION REQUIRED AT 9,500 CYCLES. OIL CONTROL NR 296869.