What was found
CENTER LANDING GEAR LT TRUNNION MATING SURFACE FOUND CORRODED. CENTER LANDING GEAR LEFT TRUNNION MATING SURFACE CORROSION REMOVED AND FOUND WITHIN LIMIT AS PER SRM 53-40-00 FIGURE 15 VOLUME I. FORWARD SIDE ORIGINAL THICKNESS = 2.485". REMOVED MATERIAL = 0.050" AND REMAINING THICKNESS = 2.435". AFT SIDE ORIGINAL THICKNESS = 2.497". REMOVED MATERIAL = 0.050" AND REMAINING THICKNESS = 2.447". REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.