What was found
MAIN CABIN SEVERE CORROSION WITH EXFOLIATION ON LONG 17 RT FROM STA 1501 TO STA 1521. REMOVED FASTENERS IN CORRODED AREA IAW SRM 51-35-01 VOL 2. REMOVED CORROSION IAW SRM 53-00-01 FIG 1B VOL 1. ORIGINAL THK IS .105" IAW DWG AEA0220 (-1). RESIDUAL THK IS 0,093", 11, 42 PERCENT MATERIAL REMOVED. REPAIR IS WITHIN LIMITS IAW SRM 53-00-01 FIG 1B VOL 1. REPROTECTED REWORKED AREA IAW SRM 51-21-01 VOL 2 PAG 21-25. REINSTALLED FASTENERS IAW SRM 51-35-01 VOL 2.