What was found
MAIN CARGO DOOR LOWER SILL AFT STUB FRAME AT STATION 560 IS CRACKED ALONG INBD RADIUS. FABRICATED AND INSTALLED NEW STUB FRAME PER FEDEX DWG 53FX1349 REV F AND SRM 51-30-02 PG 13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO DOOR LOWER SILL AFT STUB FRAME AT STATION 560 IS CRACKED ALONG INBD RADIUS. FABRICATED AND INSTALLED NEW STUB FRAME PER FEDEX DWG 53FX1349 REV F AND SRM 51-30-02 PG 13.