What was found
FOUND PREVIOUSLY REPAIR INSTALLED AT AFT CUT OUT AFT AIRSTAIRS WAS DETERMINED TO BE ACCOMPLISHED IAW SRM 51-10-1 AND SRM 51-30-1, PARA F, BASED ON AN EXTERNAL VISUAL EVAULATION, CONSISTS OF LOCATION, SIZE AND SHAPE, MATERIAL THICKNESS AND TYPE, FASTENER SPACING AND NUMBERS, GENERAL WORKMANSHIP, REPAIR IS CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.