What was found
FOUND PREVIOUSLY REPAIR INSTALLED AT R/H WING LEADING EDGE 12 INCHES OUTBD OF LANDING LIGHT WAS DETERMINED TO BE ACCOMPLISHED IAW SRM 57-30-4, FIG 2, BASED ON AN EXTERNAL VISUAL EVALUATION, CONSISTS OF LOCATION, SHAPE AND SIZE, MATERIAL TYPE AND THICKNESS, FASTENER SPACING AND NUMBERS, GENERAL WORKMANSHIP, REPAIR IS CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.