What was found
MAIN DECK COMPARTMENT FLOOR SUPPORT FOUND WITH CORROSION AT STATION 1561 RBL 91. REMOVED AS PER SRM 51-31-01 VOLUME II AND NEW FLOOR SUPPORT INSTALLED AS PER SRM 51-31-01 VOLUME II. NEW FLOOR SUPPORT FABRICATED AS PER DRAWING AFA3853. REPAIR CLASSIFIED AS MINOR PER GMM 6- 2-100.