As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK COMPARTMENT FLOOR SUPPORT FOUND WITH CORROSION AT STATION 1481 RBL 90. REMOVED AS PER SRM 51-31-01 VOLUME II AND NEW FLOOR SUPPORT INSTALLED AS PER SRM 51-31-01 VOLUME II. NEW FLOOR SUPPORT FABRICATED AS PER DRAWING AEA0364. REPAIR CLASSIFIED AS MINOR PER GMM 6- 2-100.