As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK COMPARTMENT FLOOR SUPPORT FOUND WITH CORROSION AT STATION 1853 RBL 75. REMOVED AS PER SRM 51-31-01. VOLUME II AND NEW FLOOR SUPPORT INSTALLED AS PER SRM 51-31-01 VOLUME II. NEW FLOOR SUPPORT FABRICATED AS PER DRAWING AGA3814. REPAIR CLASSIFIED AS MINOR PER GMM 6- 2-100.