What was found
MAIN DECK COMPARTMENT FLOOR SUPPORT FOUND WITH CORROSION AT STATION 5-93 RBL 08-27, AS MARKED. REMOVED AS PER SRM 51-31-01 VOLUME II AND NEW FLOOR SUPPORT INSTALLED AS PER SRM 51-31-01 VOLUME II. NEW FLOOR SUPPORT FABRICATED AS PER DRAWING AFA3853. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.