What was found
FORWARD CABIN FLOOR SUPPORT FOUND WITH CORROSION AT STATION 435 RBL 27-95. FORWARD CABIN FLOOR SUPPORT CORROSION AT STATION 435 RBL 27-95. REMOVED AND FOUND WITHIN LIMIT AS PER SRM 53-00-01 FIGURE 1A VOLUME I. MATERIAL ORIGINAL THICKNESS= 0.080", MATERIAL REMOVED=0.007", REMAINING THICKNESS=0.073". REWORKED AREA REPROTECTED AS PER SRM 51-21-01 VOLUME II AND PAINT TOUCHED UP AS PER SRM 51-21-02 VOLUME II. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.