What was found
FRAME AT STA 950C 4 INCHES RT OF CENTER LINE IS CORRODED. REMOVED DAMAGE, FABRICATED, ALODINED, PRIMED AND INSTALLED FRAME REPAIR AT STA 950C LBL 4 TO RBL 4 ALL IAW FX B727 SRM 53-10-4 FIG12,51-30-2,53-10-1, 53-10-2 AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME AT STA 950C 4 INCHES RT OF CENTER LINE IS CORRODED. REMOVED DAMAGE, FABRICATED, ALODINED, PRIMED AND INSTALLED FRAME REPAIR AT STA 950C LBL 4 TO RBL 4 ALL IAW FX B727 SRM 53-10-4 FIG12,51-30-2,53-10-1, 53-10-2 AND 51-10-2.