What was found
FOUND PREVIOUSLY REPAIR INSTALLED AT STA 720E STR 19L WAS DETERMINED TO BE ACCOMPLISHED IAW SRM 53-30-3, FIG 4 BASED ON AN EXTERNAL VISUAL EVALUATION CONSISTS OF LOCATION, SHAPE, SIZE, MATERIAL THICKNESS AND TYPE, FASTENER SPACING AND NUMBERS, GENERAL WORKMANSHIP AND REPAIR IS CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.