What was found
STA 1696 X = 27.5 EXISTING SEAT TRACK PLUG REPAIR. REMOVED CHANNEL IAW SRM 51-31-01 PAR 36/41 VOL 2. CLEANED CORROSION IAW SRM 51-21-01 PAR 34 VOL 2 VERIFICATED LIMITS IAW SRM 53-70-00 FIG 2 SHT 2 VOL 1 ORIGINAL THK IS .562 INCH IAW SRM 53-70-00 SHT 2 FIG 2 VOL 1, RESIDUAL THK IS .560 INCH % REMOVED MATERIAL IS 0.3 THK IS IN LIMITS IAW SRM 53-70-00 FIG 2 VOL 1. TREATED AREA IAW SRM 51-21-01 PAR 36/41 VOL 2 PERFORMED VISUAL INSP. REPAIR FOUND IN COMPLIANCE WITH CRITERIA REQUEST OF EO 8-5100-7-5001 P2.