SDR 06FDEA0954

Service difficulty report · Inverter · Doug DC1010

Difficulty date
March 6, 2006
Submitted
March 7, 2006
Operation
Air carrier
Aircraft
N68059
Make and model
Doug DC1010
Aircraft serial
46907
Aircraft time
51,199 hours, 24,225 cycles
Part
Inverter
Part number
527000001191
Part serial
221
Condition
Failed
Location
Zone 100
Part time
16,894 hours, 7,333 cycles
Stage of operation
TX
How discovered
O
Nature of condition
G, J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON TAXI-OUT GOT DC 2 BUS OFF LIGHT WHICH RESET ITSELF AFTER 3 SECONDS. AFTER CONFIGURING THE A/C FOR T/O, THE BATT BUS OFF LIGHT CAME ON & STICK SHAKER/TAKEOFF WARNING CAME ON. GOT ELEV FEEL & FLAP LIMIT LIGHTS ON. LOST FRONT PANEL GEAR INDICATIONS. SMELLED SMOKE FUMES AS WE'RE TAXIING INTO CHOCKS. REMOVED AND REPLACED STATIC INVERTER AS PER MM 24-24-01-2. CYCLED BATT DIR AND LEFT EMER DC FEED C/B. ALL POWER RESTORED TO NORMAL CONFIG. RAN ALL 3 ENG PER JRH CHPT 5, PERFORMED PREFERENTIAL GEN CHECKS. RAN A/C ON GROUND PWR, ENG PWR, APU PWR, EMERGENCY PWR. ALL CHECKS NORMAL.