What was found
MAIN DECK COMPARTMENT FLOOR SUPPORT FOUND WITH CORROSION AT STATION 5-73 RBL 47-75. CORRODED FLOOR SUPPORT AT STATION 5 - 73 RBL 47 - 75 REMOVED AS PER SRM 51-31-01 VOLUME II AND NEW FLOOR SUPPORT INSTALLED AS PER SRM 51-31-01 VOLUME II. NEW FLOOR SUPPORT FABRICATED AS PER DRAWING AEA7326. REPAIR CLASSIFIED AS MINOR PER GMM 6- 2-100.