Service difficulty report · Pump · Airbus A310324

Difficulty date
March 16, 2006
Submitted
March 23, 2006
Operation
Air carrier
Aircraft
N815FD
Make and model
Airbus A310324
Aircraft serial
638
Aircraft time
27,390 hours, 7,480 cycles
Part
Pump
Condition
Failed
Location
Fuel Boost
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

1.5 HR INTO FLT, FL320 RT CTR PUMP FAULT, QRH'D 1/2 HR LATER CTR TK QTY FAILED (2300LBS SHOWING) AND SOME FEEDING FROM OUTERS. REMOVED AND REPLACED CENTER TANK RT BOOST PUMP IAW A310-300 MM 28-21-36. OPS CHECK GOOD PER ABOVE MM REF. REMOVED AND EPLACED FQI COMPUTER IAW A310 MM 28-42-38 AS A PRECAUTIONARY. RELEASED FOR SERVICE PER MEL/CDL: 28-28-26-01-B CATEGORY: C EXPIRATION: 26MAR06 "MEL 28-28-26-01-B: CGCC - INOP." REMOVED AND REPLACED FUEL QUANTITY ATTITUDE SENSOR PER MM 28-42-43-4. PERFORMED DIAGNOSTIC TEST PER MM 28-42-00-5. OP CKS NORMAL.