SDR 06FDEA1275

Service difficulty report · Shutoff Valve · Doug MD11

Difficulty date
March 31, 2006
Submitted
April 3, 2006
Operation
Air carrier
Aircraft
N615FE
Make and model
Doug MD11
Aircraft serial
48767
Aircraft time
35,821 hours, 7,965 cycles
Part
Shutoff Valve
Condition
Malfunctioned
Location
Nr 2 Anti-Ice Sy
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON CLIMB-OUT AT APPROX 8,000 FT RECEIVED ENGINE 2 A/ICE DUCT ALERT. COMPLIED W/CHECKLIST LIGHT WENT OUT AT IDLE. RTB FOR UNEVENTFUL LANDING. PERFORMED FIM 30-22-05, NO LEAK DETECTED ON ENG NR 2 ANTI-ICE DUCT. ENG NR 2 COWL ANTI-ICE SHUTOFF VLV, FOUND DEFERRED OPEN. REMOVED AND REPLACED ENG NR 2 INLET COWL ANTI-ICE SHUTOFF VALVE AS PER MD11 MM 30-22-01-41. PERFORMED INSPECTION OF PICCOLO TUBES FOUND NIL ABNORMALITIES. PERFORMED ENG RUN-UP AS PER JRH FOR APU AND ENG NR 2 PNEUMATIC SYS DECAY CHECK, DONE. PASSED. ALSO, PERFORMED HIGH POWER ENG RUN-UP AS PER JRH. OPS CHECKED, NORMAL.