What was found
LT A/C BAY STR 49 HAS NUMEROUS SPOTS OF CORROSION ALONG RIVETED AREAS, TOP/SIDE SKIN OF VERTICAL FLANGE BETWEEN FR 39-40/41-42-43-44 AS MARKED. REMOVED RIVETS AND BRACKETS TO ACCESS CORROSION PER A310 SRM 51-40-21, REMOVED CORROSION ON STRINGER 49 LT PER A310 SRM 51-74-10, MEASURE MAT'L LOSS, CHECKED LIMITS FOUND 1 SPOT OUT OF LIMITS AND ALL OTHER AREAS WITHIN LIMITS PER A310 SRM 53-10-00 FIG 103 TABLE 102. REPAIRED 1 SPOT LOCATION NR 1 DETAIL H PER FEDEX EA6-5315-98983, REINSTALLED ALL RIVETS AND BRACKETS PER A310 SRM 51-40-21, ALODINED, PRIMED AND TOP COATED ALL AREAS PER A310 SRM 51-75-10.