What was found
FOUND PREVIOUSLY REPAIR INSTALLED AT STA 1140 STR 29L WAS ACCOMPLISHED IAW SRM 53-30-3 FIG 3 BASED ON AN EXTERNAL VISUAL EVALUATION, CONSISTS OF LOCATION, SHAPE, SIZE, FASTENER SPACING AND NUMBERS, MATERIAL TYPE AND THICKNESS. REPAIR IS CLASSIFED AS MAJOR PER FEDEX GMM 6-2-100.