What was found
FOUND PREVIOUSLY REPAIR INSTALLED AT NR 6 KRUGER FLAP WAS ACCOMPLISHED IAW SRM 57-50-3. BASED ON AN EXTERNAL VISUAL EVALUATION CONSISTS OF LOCATION, SHAPE, SIZE, FASTENER SPACING AND NUMBERS, MATERIAL TYPE AND THICKNESS, GENERAL WORKMANSHIP AND REPAIR IS CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.