What was found
FOUND PREVIOUSLY REPAIR INSTALLED AT STA 685 STR 29R WAS ACCOMPLISHED IAW SRM 53-30-3 FIG 3 BASED ON AN EXTERNAL VISUAL EVALUATION CONSISTS OF LOCATION, SHAPE, SIZE, FASTENER SPACING AND NUMBERS, MATERIAL TYPE AND THICKNESS, GENERAL WORKMANSHIP AND REPAIR IS CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.