As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLAP SYS 2 FAULT LIGHT ILLUMINATED ON OVERHEAD PANEL WITH ASSOCIATED FLAP FAULT ON ECAM. FOLLOWED QRH. F/O HAD NO HOOK INDICATION. COULD NOT RECOVER SYSTEM. EMERGENCY DECLARED. FOUND NR 2 SFCC FLAP FAULT SHOWING 5 FAULT BALLS = BAD SFCC. PART NIS RDU. RESET C/W. CYCLED FLAPS UP DOWN SEVERAL TIMES, CHECKED GOOD. TEST PER MM 27-51-0 0-5 GOOD. PLACED NR 2 SFCC ON MEL. COMPUTER REMOVED AND REPLACED THE NR 2 SFCC PER A300-600 MM 27-51-18-4, OPS CHECKS GOOD PER A300-600 MM 27-51-00-5, SYSTEM OK FOR SERVICE.