What was found
COMPLY WITH AGING 9-AGING-INSP REV NR POS PT1, PREVIOUS REPAIR FOUND LOCATED LT FS 3998-4059, FS 74-75 AND STR 2-5, FLUSH REPAIR. REPAIR REQUIRES EVALUATION FOR MAJOR MINOR DETERMINATION AND IF THE REPAIR WAS ACCOMPLISHED USING FAA APPROVED DATA. EXISTING REPAIR EVALUATED AND FOUND TO CONFORM TO SRM 53-18-12 ( FIG. 1 SHEET 1, DETAIL A) AND SRM 53-18-14 (FIG.1 SHEET 3, DETAIL D) AND AIB FAX REF. 942-044699/005/2006 REPAIR EVALUATED PER GMM 6-2-100 AND CLASSIFIED AS "MAJOR"