As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
COMPLY WITH AGING 9-AGING-INSP REV NR POS PT1, PREVIOUS REPAIR FOUND LOCATED ON THE RT OUTBD FLAP T/E WEDGE UPPER SURFACE INBD OF NUMBER THREE FLAP TRACK, WS 713-728. EXISTING REPAIR EVALUATED AND FOUND NOT TO CONFORM TO EXISTING REPAIR OF SRM 57-53-12 FIG. 208 SHEET 2 NEW REPAIR ACCOMPLISHED PER SRM 57-53-12 FIG. 208 SHEET 2 REPAIR EVALUATED PER GMM 6-2-100 AND CLASSIFIED AS MAJOR.