As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
COMPLY WITH AGING 9-AGING-INSP REV NR POS PT1, PREVIOUS REPAIR FOUND LOCATED ON THE RT OUTBD FLAP T/E WEDGE UPPER SURFACE OUTBD OF NUMBER THREE FLAP TRACK, WS 913-933. REPAIR EVALUATED AND FOUND NOT TO CONFORM TO AN EXISTING SRM REPAIR . NEW REPAIR ACCOMPLISHED PER FEDEX E.A. 6-5710-99706 REPAIR EVALUATED PER GMM 6-2-100 AND CLASSIFIED AS "MAJOR"