What was found
PRESSURE BULKHEAD FR 54 DENTED 4 FASTENERS ROW UP FROM FLOOR LEVEL ABOVE LT OUTBOARD MOST ROLLER TRACK AFT CARGO PIT. REPAIRED AREA IAW EA 6-5310-100991.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PRESSURE BULKHEAD FR 54 DENTED 4 FASTENERS ROW UP FROM FLOOR LEVEL ABOVE LT OUTBOARD MOST ROLLER TRACK AFT CARGO PIT. REPAIRED AREA IAW EA 6-5310-100991.