SDR 06FDEA2464

Service difficulty report · Priority Valve · Airbus A300*

Difficulty date
July 6, 2006
Submitted
July 7, 2006
Operation
Air carrier
Aircraft
N660FE
Make and model
Airbus A300*
Aircraft serial
759
Aircraft time
16,488 hours, 8,724 cycles
Part
Priority Valve
Part number
459901
Part serial
2382
Condition
Malfunctioned
Location
Hyd System
Part time
16,487 hours, 8,720 cycles
Stage of operation
TO
How discovered
O
Nature of condition
K, J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HYD YELLOW RSVR LO LEVEL M/C AT 90 KTS ON TAKEOFF KMHT. RETURNED TO RAMP. OVR YELLOW QTY READ "ZERO". RT ECAM HYD PAGE READ FULL QTY. NO PRESSURE NOTED YELLOW SYS. FOUND BLUE/YELLOW PRIORITY VALVE IN STAB COMPT BROKEN APART. REMOVED AND REPLACED VALVE, SERVICED AND BLED SYSTEM, AND PERFORMED 1 AND 2 ENGINE RUN. STAB SYSTEM CHKD NORMAL AND NO LEAKS NOTED. MM REF: 27-44-16-4, 29-11-32-4-01; 12-12-29-0. ENGINE RUN IAW A300 JRH CHAP 5A. PREMATURE REMOVAL/INSTALLATION OFF MFG 45990-1.