As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK FOUND APPROX 10" IN LENGTH DURING HFEC INSPECTION ON RT WING TANK AT THE END OF STRINGER 11 (UPPER STRINGER) AT APPROX WING STA XORS 704. REPAIRED AS PER SRM 57-20-00 FIGURE 10 VOLUME I. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.